BCM-2401 Euro - Branch Circuit Monitor CT's included not shown. pmad414
END OF LIFE JUNE 2017 SEE BCM2
KIT 01
BCM-2401 Branch Circuit Meter with monitoring for 3 mains lines and 21 branch circuits. Includes 3 x 250A mains splitcore CTs (1%) and 21 x 32A branch split-core CTs (2%)
Intelligent Branch Circuit Monitoring
Budget-friendly circuit monitoring to enable smart
energy management
Today, there is an increasing need to monitor power consumption to minimize costs and meet corporate green initiatives including minimizing carbon footprint. In some areas of the world, such as Europe, there are regulations such as ISO/IEC 62053 standards for energy monitoring. Raritan’s intelligent Branch Circuit Monitoring (BCM) appliance meets or exceeds these directives.
Raritan’s BCM provides power and energy data on branch circuits and mains in an electrical service entrance or a remote power panel. It provides an accurate view of electrical capacity, energy use, and monitoring for uptime and reliability. Any time a circuit’s current approaches a breaker’s limit, BCM sends an alarm, helping you to prevent potential problems. Customizable alarms allow the operator to easily set sensitivity parameters triggering an alarm when the load on any breaker approaches its limit.
Increase your billing accuracy and properly charge customers for their true energy costs instead of a general energy charge per section of assigned space. Data from BCM enables you to show or charge customers and departments based on actual energy consumption. Customers or departments that use more power and require more infrastructure are charged accordingly.
Why intelligent branch circuit monitoring?
-Support energy saving and green initiatives
-Analyze actual usage per circuit against your budget to determine if it can support additional loads
-Attain a granular view of power and energy use to pinpoint areas for optimization or areas in need of additional capacity
-Set alarms on amperage conditions for individual panel breakers so you stay within mandated regulations.
-Improve balancing of loads
-Allocate costs to specific users, customers, and departments
-For data centers, monitor breakers so as not to exceed recommended capacity limit in dual-feed equipment racks.
BCM Series
Raritan’s Intelligent Branch Circuit
Monitoring (BCM) solution
has the ability to monitor power
and energy at the mains (input)
and branch circuit level.
3 Mains Lines:
uuRMS current per line (A)
uuRMS voltage per line pair (V)
-Active power (W)
-Apparent power (VA)
-Power factor (PF)
- Mains active energy (Watt hours) at ISO/IEC +/- 1%
- Unbalanced load percentage (three phase only)
21 Branch Circuits:
-RMS current (A)
-RMS voltage (V)
-Active power (W)
-Apparent power (VA)
-Power factor (PF)
- Branch active energy (Watt hours) at ISO/IEC +/- 1%
- Unbalanced load percentage (three phase only)
Other features:
-Meets ISO/IEC 62053 standards
- Supports up to 16 external optional sensors
- Network accessible via 10/100 Ethernet or WiFi
-Web browser accessible
- Manageable via open interfaces: SNMP, SSH, HTTP/S, with full scripting JSON-RPC
/BCM-2401 Euro - Ports and terminal view
KIT 01
BCM-2401 Branch Circuit Meter with monitoring for 3 mains lines and 21 branch circuits. Includes 3 x 250A mains splitcore CTs (1%) and 21 x 32A branch split-core CTs (2%)
BCM-Eng-May13
Model Description
BCM-2401-KIT-02 BCM-2401 branch circuit meter with monitoring for 3 mains lines and 21 branch circuits. Includes 3 x 250A mains splitcore
CTs (1%) and 21 x 100A branch split-core CTs (1%)
BCM-2401-KIT-01 BCM-2401 branch circuit meter with monitoring for 3 mains lines and 21 branch circuits. Includes 3 x 250A mains splitcore
CTs (1%) and 21 x 32A branch split-core CTs (2%)
BCM-2401 BCM-2401 branch circuit meter with monitoring for 3 mains lines and 21 branch circuits. (no CT’s bundled)
BCM display and ports
BCM terminal connections
BCM available sensors
BCM available models
- Smart LCD display allows you to scroll
through main and branch circuit
information at the power panel
- Flexible and versatile connections for
10-100 Mbps Ethernet, RS-232 serial,
Feature/KVM, USB-A (host),
Compatible Sensors :
RJ-12 connector to combined temperature/
humidity sensor, and additional 3m (10 ft) between additional combined temperature/humidity sensor (total length 6m/20 ft)
DPX-T3H1 Three temperatures, with the middle temperature also supporting humidity (four sensors total in three sensor housings).
RJ-12 connection to the PX®/PX2 PDU. 4m (13 ft) cable length from RJ-12 to first sensor, 3 ft (1m) between first and
second and second and third sensor housings
DPX-AF1 Single airflow sensor – 3m (10 ft) cable length – RJ-12 connector
DPX-T1DP1 Single combo differential pressure and temperature sensors – 3m (10 ft) cable length – RJ-12 connector
DPX-CC2-TR Dual contact closure sensor – requires customer-provided Normally Closed (NC) or Normally Open (NO) switch like door
open/closed, door locked/unlocked, smoke present/absent. Factory default is NC. Each of the two ports (channels) can be
independently set to NC or NO. RJ-12 connector
DPX-ENVHUB4 Four-port hub for DPX-xxxx sensors only; comes with mounting bracket and RJ-12-to-RJ-12 cable to connect to and receive
power from all PX and EMX models
AMS-42 Asset Management Sensor kit for 42U height rack. 1 connector and 1 RGB LED per U space. RJ-45 connector
AMS-45 Asset Management Sensor kit for 45U height rack. 1 connector and 1 RGB LED per U space. RJ-45 connector
AMS-48 Asset Management Sensor kit for 48U height rack. 1 connector and 1 RGB LED per U space. RJ-45 connector
AMS-54 Asset Management Sensor kit for 54U height rack. 1 connector and 1 RGB LED per U space. RJ-45 connector
AMT-100 100-pack of intelligent Asset Management Tags for AMS- with electronic ID and bar code
Smart controller and sensor options for data centers of all sizes
Dual contact closure sensor
Single airflow sensor
Single temperature sensor
Single combo differential pressure and
temperature sensors
Single combo temperature and
humidity sensors
Simplified branch power monitoring
visit www.raritan.eu/BCM
© 2013 Raritan Inc. All rights reserved. Raritan®, Know more. Manage smarter.™, Power IQ®, PX® and dcTrack® are registered trademarks or trademarks of Raritan Inc. or its
wholly-owned subsidiaries. All others are registered trademarks or trademarks of their respective owners.